RadicalScope mt 500-L (L-Band, 1 - 1.5 GHz)
Detectable Species for Quantification
- Free radicals in vivo or in samples with high water content
Spatial Signal Resolution
- Spectral, spectral-spatial, 2D imaging and 3D imaging in dependence of gradient systems for spatial signal resolution
Object of Investigation
- Mouse, rat, skin, tooth, tissue
Temperature of the Sample
Resonators
- Surface coil resonator, with automatic matching control, compensating movements e. g. breathing of an animal, coil diameter 8 and 10 mm
- Re-entrant resonator, highest sensitivity, suitable for measurement in the tail or head of a rat, accessible diameter 18 mm
|
 |
Detection Limit
- Depends on type of resonator and the filling factor
- Re-entrant resonator: 1 µM signal to noise ratio 5 : 1, TEMPOL in 50 mM phosphate buffer, pH 7,4
Spatial Resolution of EPR Signals
- Spatial signal resolution 0.1 mm for spectral spatial and 1 mm for 2D and 3D imaging in dependence on the line width of the signal
Three 200 µl capillaries orientated and filled the way shown above.The y-axis gives the spatial information about the distance; the x-axis shows the spectral information.
|
| |
Delivery
|
- Magnet especially designed for L-band
- Magnet power supply
- Microwave bridge
- Power supply for control and microwave bridge
- Computer and 17'' TFT monitor
- Standard-Software
RadicalScope Control
(control software):
- Adjust of the measurement parameters
- Manual tuning
- Recording of Spectra
- Saving of data
- 4096 data points per spectrum, etc.
Extensions for the RadicalScope mt 500-L you can find in the  Catalogue (EPR Spectrometer)
Technical Data
|
|
- Analysis (calculation software):
- Amplitude calculation
- Integration
- Baseline correction
- Filtering
- g-value estimation
- Summation of spectra, etc.
- Multiplot (presentation software):
- Overlay of spectra
- Display of spectra in series
- Adaptation of the gain
- X-Axis title selection: data points, field or time
- Export of data in ASCII files, etc.
|
Computer System
 |
 |
 |
| Processor |
|
from Pentium II upwards |
| Operating system |
|
Microsoft Windows 98 SE, 2000 und XP |
| Interface |
|
PC controlled by Sorcus board |
Microwave Bridge
 |
 |
 |
| Microwave power |
|
100 µW - 100 mW |
| Microwave frequency |
|
1 - 1.5 GHz |
| Control |
|
Control Unit CU5 |
| Tuning |
|
Manual tuning |
Magnet Power Supply
 |
 |
 |
| Stability |
|
10-6/min |
| Output power |
|
500 W |
Optional Resonators
Surface coil resonator
Re-entrant resonator
|
|
Electro Magnet
 |
 |
 |
| Modulation amplitude |
|
0.5 µT - 0.5 mT |
| Modulation frequency |
|
100 kHz |
| Magnetic field range |
|
0 - 65 mT |
| Field sweep |
|
0 - 50 mT |
| Sweep time |
|
10 s - 2 h |
| Stability |
|
2.5 µT/min |
| Homogeneity |
|
10-5/2 cm3 |
Free gap size
(without modulation and tomography coils) |
|
150 mm |
| Weight |
|
500 kg |
| Cooling |
|
air, water in the case of 1D to 3D extensions |
Extensions for Imaging
|
|
| |
|
|

 |
 |
 |
 |
 |
 |
| magnettech GmbH |
| Analysenmesstechnik |
| Louis-Blériot-Str. 5, D-12487 Berlin |
| phone: |
+49 30 6780 2526 |
| fax: |
+49 30 6322 4101 |
| e-Mail: |
info@magnettech.de |
|
 |
 |
|
|
|
| |
|